EasyManua.ls Logo

Estun pronet series - Reference Pulse Inhibit Function (INHIBIT)

Estun pronet series
193 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProNet Series AC Servo User's Manual
- 103 -
4.6.7 Reference Pulse Inhibit Function (INHIBIT)
(1)Description
This function inhibits the servo drive from counting input pulses during position control.
The servomotor remains locked (clamped) while pulses are inhibited.
Error Counter
+
-
Feedback pulse
OFF
ON
Pn005.1
Pn005=H.□□1
Pn005=H.□□B□
Reference pulse
/P-CON
/P-CON
Servodrive
(2)Setting Parameters
Parameter Meaning
Pn005
H.□□B□
Control mode selectionposition control(pulse train reference)INHIBIT
Inhibit(INHIBIT) switching condition
·/P-CON signal ON (low level)
(3)Setting Input Signals
Type
Signal
Name
Connector Pin
Number
Setting Meaning
Input /P-CON CN1-15
ON(low level)
Turns the INHIBIT function ON.
(Inhibit the servo drive from counting reference
pulses)
OFF(high level)
Turns the INHIBIT function OFF.
(Counters reference pulses.)

Table of Contents

Related product manuals