5.2 Operation in Utility Function Mode
In utility function mode, the panel operator can be used to run and adjust the servo drive and servomotor.
The following table shows the parameters in the utility function mode.
Note: Fn010Fn011 only can be used when the servomotor mounted the absolute encoder.
5.2.1 Alarm Traceback Data Display
The alarm traceback display can display up to 10 previously occurred alarms.The alarm is displayed on Fn000, which is
stored in the alarm traceback data.
Follow the procedures below to confirm alarms which have been generated.
1. Press the MODE key to select the utility function mode.
2. Press the INC or DEC key to select the function number of alarm trace back data display.
3. Press the ENTER key once, the latest alarm data is displayed.
Alarm Sequence Number Alarm Code
4. Press the INC or DEC key to display other recent alarms that have occurred.
5. Press the ENTER key, the display will return to Fn000.
Note: Hold the ENTER key for one second with alarm code displaying, all the alarm traceback datas will be cleared.
Parameter No. Function
Fn000 Alarm traceback data display
Fn001 Parameter setting initialization
Fn002 JOG mode operation
Fn003 Automatic adjustment of speed reference offset
Fn004 Manual adjustment of speed reference offset
Fn005 Automatic adjustment of servomotor current detection
Fn006 Manual adjustment of servomotor current detection
Fn007 Software version display
Fn008 Position teaching
Fn009 Static inertia detection
Fn010 Absolute encoder multiturn data and alarm reset
Fn011 Absolute encoder related alarms reset

Table of Contents