EasyManua.ls Logo

Estun pronet series - Page 173

Estun pronet series
193 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProNet Series AC Servo User's Manual
- 171 -
Parameter
No.
Description
Setting
Validation
Control
Mode
Function and Meaning
t1
t2
PCON disabled
PCON enabled
PCON disabled
Reference pulse
Pn201
Electronic gear numerator 1
Pn203
Electronic gear numerator 2
Pn201
Electronic gear numerator 1
t1t2>1ms
[1] Corresponding time sequence
Time sequence when Pn002.0=0 or 1
Error time sequence
Pn002.1 Reserved
Pn002.2 Absolute encoder selection
[0] Use absolute encoder as an absolute encoder
[1] Use absolute encoder as an incremental encoder
Pn002.3 Reserved
Pn003
Binary After restart ALL
Pn003.0 Reserved
Pn003.1 Reserved
Pn003.2 Low speed compensation
[0] Without low speed correction
[1] With low speed correction to avoid servomotor
creeping, but the degree of correction is
determined by the setting in Pn219.
Pn003.3 Overload enhancement
[0] Without overload enhancement function
[1] With overload enhancement function, which can
enhance the overload capacity when servomotor
exceeds the 2 times rated overload. It is used in
frequent power ON/OFF occasions.

Table of Contents

Related product manuals