ProNet Series AC Servo User's Manual
- 28 -
3. External regenerative resistor for ProNet-02A~04A/ProNet-E-02A~04A is provided by customer, the model of 60W,
50Ωresistor is recommended.
4.Change Pn521.0 from “1” to “0” when using the external regenerative resistor in ProNet-02A~04A/ProNet-E-02A~04A
servo drives.
·Three-phase 200V ProNet-08A~50A/ Three-phase 200V ProNet-E-08A~50A
Noise Filter
L1 L2 L3
Three-phase 200~230V (50/60Hz)
+10%
-15%
Power OFF Power ON
1KM 1SUP
1KM
1Ry
L1
L2
L3
W
V
U
M
PG
Servomotor
Encoder
A(1)
B(2)
C(3)
D(4)
L2C
L
1C
CN2
1Ry
1D
+24V
0V
Surge Protector
Magnetic Contactor
Molded-case Circuit Breaker
1Ry
1PL (Servo Alarm Display)
ALM+7
ALM-
8
Be sure to connect a surge suppressor to the
excitation coil of the magnetic contactor and relay.
.
ProNet
Series Servodrives
1
2
B1
B2
B3
B2
B1
External Regenerator Resistor
B3
Ground Terminal
Three-phase 400V ProNet-10D~75D
/ Three-phase 400V ProNet-E-10D~50D
Noise Filter
L1 L2 L3
Three-phase 380~440V (50/60Hz)
+10%
-15%
Power OFF Power ON
1KM 1SUP
1KM
1Ry
L1
L2
L3
W
V
U
M
PG
Servomotor
Encoder
A(1)
B(2)
C(3)
D(4)
CN2
1Ry
1D
+24V
0V
Surge Protector
Magnetic Contactor
Molded-case Circuit Breaker
1Ry
1PL (Servo Alarm Display)
ALM+7
ALM-
8
Be sure to connect a surge suppressor to the
excitation coil of the magnetic contactor and relay.
.
ProNet
Series Servodrives
1
2
B1
B2
B3
B2
B1
External Regenerator Resistor
B3
Ground Terminal
GND
24V
24VDC Power Supply