ProNet Series AC Servo User's Manual
- 44 -
3.5.5 Single-phase 100V ProNet-02B/ProNet-E-02B
Noise Filter
L1 L2
single-phase 100~120V (50/60Hz)
+10%
-15%
Power OFF Power ON
1KM 1SUP
1KM
1Ry
L1
L2
1
2
W
V
U
M
Servomotor
A(1)
B(2)
C(3)
D(4)
L2C
L
1C
+
A/D
CN1
CN2
2KΩ
150Ω
150Ω
2KΩ
PULS / CW / A
SIGN / CCW / B
Connect Shield to Connector Shell.
Open-collector Reference Use
Speed Reference(±0~10V/Rated Speed)
Torque Reference (±0~10V / Rated Torque)
Position Reference
Signal allocatons can be modified:
S-ON: Servo ON
P-CON: P Control
P-OT: Forward Run Prohibited
N-OT: Reverse Run Prohibited
ALM-RST: Alarm Reset
CLR: Clear Error Pulse
P-CL: Forward Torque Limit
N-CL: Reverse Torque Limit
SHOM: Home
ORG: Zero Position
+24V
PP P P
PG Divided Ratio Output:
Applicable Line Receiver
AM26LS32A Manufactured by TI or the Equivalent.
P
Represents Twisted-pair Wires
-
-
+
ref
ref
40K
10K
40K
10K
CN3
CN4
Use special communication cable to connect
PC(Personal Computer).
1Ry
1D
+24V
0V
Surge Protector
Molded-case Circuit Breaker
1Ry
1PL (Servo Alarm Display )
1
2
485+3
ISO_GND
4
ISO_GND
5
485-6
CANH7
CANL8
N.C.1
N.C.2
485+3
ISO_GND
4
ISO_GND
5
485-6
CANH7
CANL8
PAO+20
PAO-21
PBO+22
PBO-23
PCO+24
PCO-
25
DGND50
TGON+5
TGON-6
S-RDY+9
S-RDY-
10
V-CMP+11
V-CMP-12
ALM+7
ALM-8
VREF+ 1
VREF-
2
TREF+ 26
TREF- 27
PPI 34
PULS+ 30
PULS- 31
SIGN+ 32
SIGN- 33
DICOM 13
S-ON 14
P-CON 15
P-OT 16
N-OT 17
ALM-RST
39
CLR 40
P-CL 41
N-CL 42
Shield
Shell
Shield
Shell
Shield
Shell
Be sure to connect a surge suppressor to the
excitation coil of the magnetic contactor and relay.
Be sure to ground
Signal Allocations can be Modified:
V-CMP: Speed Coincidence
COIN: Positioning Completion
TGON:Rotation Detection
S-RDY:Servo Ready
CLT:Torque Limit Detection
BK:Brake Interlock
PGC: Encoder C-Pulse Output
OT:Over Travel
RD: Servo Enabled Motor Excitation Output
HOME: Home Completion Output
ALM: Servo Alarm Output
Photocoupler Output:
Maximum Operating Volt age:DC30V
Maximum Output Current:DC50mA
3.3KΩ
N.C.
N.C.
Note: Do not short terminal 1 and 2 of CN3.
B1
B2
B3
B1
B2
B3
External Regenerator Resistor
Encoder
Be sure to prepare the end of the
shielded wire properly.
PG
A+1
A-2
B+3
B-
4
PG5V
5
PG0V
6
7,8,9
17,18,19
Shell
C+
C-
Shield
Incremental Wire-saving
Encoder(2500P/R)
S+7
S-8
BAT+17
BAT-18
PG5V9
PG0V19
Shield
Serial Encoder
Shell
Option