1.7 System Configuration
Example Diagram
Main Power Supply
Cable
Motor Power Supply
Cable
Servomotor
External Encoder Cable
Magnetic
Contactor
Circuit
Breaker
External
Regenerative
Resistor
Encoder Cable
I/O Signals Cable
EtherCAT Cables
USB Cable
Power Supply
Three-phase, 200 VAC to 240 VAC
Control Power Supply
Cable
Noise
Filter
Peripheral Devices Specification
Device Name
Description
Specification
Circuit Breaker
Uses to protect the power supply
line and cut off the circuit when an
overcurrent occurs.
The minimum rated current of the circuit
breaker depends on the Drive model.
ED3S-A5A*, 01A*, -02A*, -04A*: 10A
ED3S-08A*, -10A*: 25A
ED3S-15A*: 35A
ED3S-20A*: 55A
ED3S-30A*: 70A
Noise Filter
Used to prevent external noise
interference from the power supply.
The rated current is 10A or 20A.
External
Regenerative
Resistor
When the busbar capacitance is
insufficient, remove the short
wiring between B2 and B3, and
connect an external regenerative
resistor between B1 and B2.
(1)
The minimum value of the regenerative
resistor depends on the Drive model.
ED3S-A5A*, 01A*, -02A*, -04A*: 50Ω
ED3S-08A*, -10A*: 25Ω
ED3S-15A*, -20A*, -30A*: 10Ω
(1): ED3S-A5*, ED3S-01*, ED3S-02* and ED3S-04* must connect an external regenerative resistor.