EasyManua.ls Logo

Estun Summa Series - Chapter 3 Wiring and Connecting; USB Communication Cable; Wiring the External Encoder

Estun Summa Series
346 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Summa Series Servodrive Product Manual
Installation
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
2-2
2.3 Mounting Hole Dimensions
Use two or three mounting holes to securely mount the Drive to the mounting surface.
To mount the Drive, you will need to prepare a screwdriver that is longer than the depth of the Drive.
ED3S-A5*ED3S-04* ED3S-08*ED3S-15* ED3S-20*ED3S-30*
Exterior
2 × M4
5
164±0.5
(mounting pitch)
172
5
28±0.5
(mounting pitch)
38
5
164±0.5
(mounting pitch)
172
5
55±0.5
(mounting pitch)
65
Exterior
2 × M4
5
164±0.5
(mounting pitch)
172
5
85±0.5
(mounting pitch)
95
Exterior
3 × M4
2.4 Mounting Interval
Installing One Drive in a Control Cabinet
Provide enough space around the Drive when installing one Drive in a control cabinet, as is shown in
Figure 2-2.
Figure 2-2 Install one Drive in a control cabinet
50mm
30mm
50mm
30mm
75mm
Wiring allowance
Mounting allowance between mounting plate
and cabinet shall be not less than 6.4 mm
Mounting
plate

Table of Contents

Related product manuals