2-4
2.5 EMC Installation Conditions
This section gives the installation conditions that were used for EMC certification testing.
2.5.1 EMC Directives
The EMC installation conditions that are given here are the conditions that were used to pass testing
criteria at ESTUN. The EMC level may change under other conditions, such as the actual installation
structure and wiring conditions. These ESTUN products are designed to be built into equipment.
Therefore, you must implement EMC measures and confirm compliance for the final equipment.
Power Supply:
Three-phase,
200 VAC
Clamp
Noise
Filter
Drive
Brake power supply
Brake
Encoder
Motor
L1, L2, L3
L1C, L2C
U, V, W
Controller
CN2
CN1
Shield box
Cable length
2 m
Cable length 5 m
PE
PE
Clamp
Ferrite
Coil
Ferrite
Coil
Ferrite
Coil
Ferrite
Coil
Clamp
Ferrite Coil
Ferrite Coil
No
Cable Name
Specification
I/O Signal Cable
Shielded cable
Encoder Cable
Shielded cable
Motor Main Circuit Cable
Shielded cable

Table of Contents