Summa Series Servodrive Product Manual
Appendix
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
12-63
Index
Subindex
Name
Data Type
Access
PDO Mapping
Value
6074h
0
Target Demand Value
INT16
RO
Yes
Torque Slope (6087h)
This object sets the torque output slope to use in Profile Torque Mode. Set the value as the rate
of change
per second (0.1%/s) in respect to the Motor rated torque.
Index
Subindex
Name
Data Type
Access
PDO Mapping
Value
6087h
0
Target Slope
UINT32
RW
Yes
0 to 4294967295
Default: 100
Torque Actual Value (6077h)
This object contains the torque reference output value.
Index
Subindex
Name
Data Type
Access
PDO Mapping
Value
6077h
0
Torque actual value
INT16
RO
Yes
12.3.12 Torque Limit Function
Max. Torque (6072h)
This object sets the maximum output torque for the Motor in PT mode. Set the value in units of 0.1% of
the Motor rated torque.
Index
Subindex
Name
Data Type
Access
PDO Mapping
Value
6072h
0
Max Torque
UINT16
RW
Yes
0 to 65535
Default: 3000
Positive Torque Limit Value (60E0h)
This object sets the positive torque limit. Set the value in units of 0.1% of the Motor rated torque.
The positive torque limit value is the smaller of 6072h and 60E0h.
Index
Subindex
Name
Data Type
Access
PDO Mapping
Value
60E0h
0
Positive Torque
Limit Value
UINT16
RW
Yes
0 to 65535
Negative Torque Limit Value (60E1h)
This object sets the negative torque limit. Set the value in units of 0.1% of the Motor rated torque.
The negative torque limit value is the smaller of 6072h and 60E1h.

Table of Contents