Summa Series Servodrive Product Manual
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
Torque Slope (6087h)
This object sets the torque output slope to use in Profile Torque Mode. Set the value as the rate
of change
per second (0.1%/s) in respect to the Motor rated torque.
0 to 4294967295
Default: 100
Torque Actual Value (6077h)
This object contains the torque reference output value.
12.3.12 Torque Limit Function
Max. Torque (6072h)
This object sets the maximum output torque for the Motor in PT mode. Set the value in units of 0.1% of
the Motor rated torque.
Positive Torque Limit Value (60E0h)
This object sets the positive torque limit. Set the value in units of 0.1% of the Motor rated torque.
The positive torque limit value is the smaller of 6072h and 60E0h.
Positive Torque
Limit Value
Negative Torque Limit Value (60E1h)
This object sets the negative torque limit. Set the value in units of 0.1% of the Motor rated torque.
The negative torque limit value is the smaller of 6072h and 60E1h.