Summa Series Servodrive Product Manual
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
Fn000 (Alarm trace data display)
The alarm trace data display can display up to ten previously occurred alarms. The following are the steps
to display the alarm trace data.
Step 1 Press [M] key several times to select the Utility Function Mode.
Step 2 Press [▲] key or [▼] key to select the function number Fn000.
Step 3 Press [◄] key to display latest alarm number.
Step 4 Press [▲] key or [▼] key to view the other alarm data.
Step 5 Press the [◄] key to return to the display of the Fn000.
Press and hold [◄] key for 1 second or more to clear all the alarm trace data.
Fn001 (Initialize parameter settings)
The following are the steps to initialize parameter settings.
Step 1 Press [M] key several times to select the Utility Function Mode.
Step 2 Press [▲] key or [▼] key to select the function number Fn001.
Step 3 Press [◄] key, and Panel Operator displays as below.