Fn010 (Absolute encoder multi-turn reset)
The following are the steps to reset the absolute encoder multi-turn data.
Step 1 Press [M] key several times to select the Utility Function Mode.
Step 2 Press [▲] key or [▼] key to select the function number Fn010.
Step 3 Press [◄] key, and Panel Operator displays as below.
Step 4 Press [M] key to reset the absolute encoder multi-turn data.
Step 5 Press [◄] key to return to the display of the Fn010.
Fn011 (Absolute encoder alarm reset)
The following are the steps to reset the absolute encoder alarm.
Step 1 Press [M] key several times to select the Utility Function Mode.
Step 2 Press [▲] key or [▼] key to select the function number Fn011.
Step 3 Press [◄] key, and Panel Operator displays as below.
Step 4 Press [M] key to reset the absolute encoder multi-turn data.
Step 5 Press [◄] key to return to the display of the Fn011.
Fn017 (Auto-tuning tool)
This utility function often use used for tuning, refers to the section 9.3.1 Auto-Tuning Tool.
Fn018 (PJOG operation)
This utility function often use used for trial operation, refers to the section 8.5 Program Jogging.