EasyManuals Logo

evoheat Evo270 Quick Start Guide

evoheat Evo270
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
REGISTER YOUR WARRANTY ONLINE
Use your mobile phone to scan code to register your warranty online.
INSTALLATION LOCATION
1. Install the system on a level concrete pad or suitable HWS base.
2. Ensure the air inlet and outlet are clear from any obstructions.
(consult the manual for clearances)
PLUMBING CONNECTIONS
1. Connect the hot water outlet, and cold water inlet plumbing and associated valves in accordance with all
local regulations and applicable standards.
2. Install the supplied Pressure Temperature Relief (PTR) valve.
3. Connect a condensate line and run to appropriate drain.
4. Lag (insulate) all plumbing as per local regulations.
ELECTRICAL CONNECTIONS
1. Install an isolation switch within 3m of the unit.
2. Run the supplied electrical cable from the unit to the isolation switch.
3. Connect the Isolation switch with appropriate cable to a dedicated 15amp circuit at the switchboard.
FOR ADDITIONAL INFORMATION PLEASE REFER TO THE OWNERS MANUAL

Other manuals for evoheat Evo270

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the evoheat Evo270 and is the answer not in the manual?

evoheat Evo270 Specifications

General IconGeneral
ModelEvo270
CategoryHeat Pump
Water Tank Capacity270 liters
Refrigerant TypeR134a
Operating Temperature Range-7°C to 43°C
COP3.6
Power Supply220-240V, 50Hz