MAINTENANCE
.081/02-15 1-12
ITEM
DESCRIPTION INTERVAL
FINAL DRIVE
ASSEMBLY
(Continued)
Check condition of oil for condensate or other
contaminants by draining a small amount from both
oil and condensate drains and visual inspection.
M*
If clear water is present, drain until oil
becomes present and refill oil to proper
level.**
Check for damaged dust shield.
If oil is milky in color, drain, flush and refill
** with fresh oil.Check for damaged dust
shield.
Some metal contaminants (fine particles,visual
with the eye) are expected in the first six to
twelve months of service due to initial groove
formation of bearing races. If contaminates are
high in concentration or if large metallic chips
are present, take clarifier out of service. After
locking out drive starter, inspect stop blocks by
pulling back edge of neoprene drive dust
seal.If bottoms of stop blocks show signs of
contact with the top portion of the main gear or
if a stop block is missing, CALL FACTORY.
Seasonal change of oil. SA
*Or after severe weather or wash-down procedures.
**Due to the viscosity of the oil, it can take several hours for a true reading to occur at
the sight gauge. Overfilling of oil will result in oil leaking into the collector.