Opto isolated Inputs (GP In 1, 2, 3, 4)
Pin-Out
specifications
The input consists in an opto diode (VF @ 1.1 Volt) in series with a 470 ohm resistor).
Typical switching point @ 1.4 mA, for secure operation:
i=0 to 0.5 mA -> opto OFF
i=2.5 to 30 mA -> opto ON
imax= 30 mA
Direct connection to a TTL/CMOS signal possible (Pin opto - to GND and pin opto + to
the TTL/CMOS signal.
Typical switching point @ 1.6 Volts, for secure operation:
Vin< 0.8 Volts -> opto OFF
Vin> 2.2 Volts @ 2 mA -> opto ON
Vin max (without external resistor) = 15 Volts
TTL Inputs (GP In 5, 6, 7, 8)
Relay Inputs Pin-Out
The relay must be connected between the ground and the corresponding TTL input on the
DB25.
60 5. Hardware Installation and Cabling
EVS Broadcast Equipment S.A. -November 2011 Issue 11.00.A