Connector Assignments
Connector SD mode HD mode Connector label
J1 J5 is factory-wired to the backplane instead of J1. You can
connect J1 instead of J5 if CVBS monitoring is required in SD or
HD mode.
SDI monitoring is no longer available on J1.
CHAR SD
CVBS monitoring output (SD) CVBS monitoring output
(SD, down-converted)
J2 SDI monitoring output (SD) SDI monitoring output
(SD, down-converted)
Not wired to the
backplane.
Used for onboard
multiviewer input.
J3 Loop-through for the SDI input
signal (SD)
Loop-through for the SDI input
signal
(SD, down-converted)
OUT B
J4 SDI monitoring output (SD) SDI monitoring output (SD/HD) CHAR OUT SD/HD
J5 Not used Not used IN B
J6 SDI program output
(SD, identical to J7)
HD SDI program output
(HD, identical to J7)
OUT
J7 SDI program output
(SD, identical to J6)
HD SDI program output
(HD, identical to J6)
OUT
J8 SDI input (SD) HD SDI input (HD) IN
J9 Alternate SDI input
(SD, for hardware loop)
Alternate HD SDI input
(HD, for hardware loop)
Not wired to the
backplane.
Used for internal loop
in
Note
The loops of the input signal are not genlocked.
XS Serverî-îVersion 11.00î-îHardware Technical Reference Manual
6. Boards Description 67