1.5.4 CE MARKING
The CE marking is affixed to indicate compliance with the following directives:
• 89/336//EEC of 3 May 1989 on the approximation of the laws of the Members
States to electromagnetic compatibility.
• 73/23/EEC of 19 February 1973 on the harmonization of the laws of the
Members States relating to electrical equipment designed for use within certain
voltage limits.
• 1999/5/EC of 9 March 1999 on radio equipment and telecommunications
terminal equipment and the mutual recognition of their conformity.
1.5.5 POWER SUPPLY
This equipment is equipped with AUTOSWITCH and hot-swappable power supply.
Connection to supply: Pluggable equipment Type A (EN60950 §1.2.5):
Equipment which is intended for connection to the building power supply wiring via
a non-industrial plug and socket-outlet or a non-industrial appliance coupler or
both. Correct mains polarity must always be observed. Do not use reversible
power plugs with this equipment.
Class of equipment: Class 1 equipment (EN60950 § 1.2.5): electric shock
protection by basic insulation and protective earth.
Rated voltage: 115 to 240Vac (single phase)
Rated frequency: 47-63 Hz
Related Current: 8 A (100 to 120 Vac range) 4 A (220 to 240 Vac range)
Input connector: CEE22/IEC 320 3-pin male receptacle
Important
The protective earth must be connected to the ground before powering
up the unit.