4
HOW TO OPERATE
Starting your new Refrigerator
1. Clean the refrigerator thoroughly. Wipe the outside with a soft dry cloth, the
interior with a clean moist cloth.
2. Insert the power supply cord into the socket.
Temperature control
Defrosting
You will never have to defrost your refrigerator as it is designed to do it
automatically. The defrosted water drains into the evaporator tray located in
the backside.
NOTE: Wait 3-5 minutes before restarting if you unplug the refrigerator.
The unit may fail to operate properly if restarted too quickly.
3
!
#
@
$
^
&
*
(
)
1
8
7
6
3
5
4
2
%
NAMES OF THE PARTS
! ICE TRAY
@ F SHELF (MOVABLE)
# FREEZER TEMPERATURE
CONTROL KNOB
$ ICE BOX
% CHILLED CASE DOOR
^ CHILLED CASE
& REFRIGERATOR
TEMPERATURE
CONTROL SWITCH
* R SHELF (MOVABLE)
( LAMP COVER
) VEGETABLE CASE COVER
1 VEGETABLE CASE
2 FREEZER POCKET(SMALL)
3 FREEZER
POCKET(MIDDLE)
4 EGG CASE
5 UTILITY
POCKET(SMALL/SMALL)
6 UTILITY
POCKET(SMALL/MIDDLE)
7 BOTTLE
POCKET(LARGE/LARGE)
8 BOTTLE
POCKET(MIDDLE/LARGE)
Freezer Temperature Control Refrigerator Temperature Control
MIN MED
TEMP. CONTROL
MAX WINTER
MINMED
MAX
WINTER
TEMP. CONTROL
MIN When ambient Temp. is below 15˚C or 59 ˚F
MED When ambient Temp. is between 15-25˚C or 59-77˚F
MAX When ambient Temp. is above 25˚C or 77˚F
WINTER If ambient temperature is below 10˚C or 50˚F
To control the internal temperature, adjust the control dial according to the ambient
temperature or purpose of use.
The first time you turn the unit on, set the temperature control to MAX.
The range of the temperature control is from position MIN the warmest to WINTER the
coldest. After 24 to 48 hours, adjust the temperature control to the setting that best suits your
needs. The setting of MED should be correct for home or office refrigerator use.
“Winter” Position: Select the WINTER Position when the temperature in the area
where the appliance is located is colder than 10˚C or 50˚F. This enables the freezer
section to operate properly.