4.2-12
www.EWSWATER.com office: 702-256-8182 (m-f; 8:30-4:30, pst) fax: 702-256-3744 customerservice@ewswater.com
Inlet (supply) Side
Bypass
Valve
Drain
High Flow DTV 2750 Valve, Cover: Black
NEMA 1 Rated: resists dust and moisture
Hinged: left, Controls: inside
Back Side: Front Side:
Materials Needed for Installation:
Inlet and Outlet on valve are both 1” MNPT
1” and 11/4” pipe length to be determined
Qty. 3 - 1” Ball Valves
Qty. 2 - 1” Unions
Qty. 1- Union for drain line** (see proper specifications)
Union
Union
Outlet (filtered)Side
inlet
1” MNPT
56 1/2”
on center
outlet
1” MNPT
58 1/2”
on center
drain
1/2” FNPT
57 1/2”
on center
Due to tank and base variances overall dimensions +/- 1”
Materials Needed for Drain:**
1/2” MNPT copper x 1/2” (min.) male adapter
1/2” (min.) union
1/2” (min.) drain line, pipe length to be determined
**Nominal drain line and drain size should be a minimum of
1/2”. Drain line exceeding 20’ in length and/or drain water that is
expected to flow over 5’ above the height of the drain port re-
quires a 3/4” line and drain. Install, non-restrictive, check valve
in drain line, if drain water is expected to flow over 5’ above the
height of the drain port . Never restrict the backwash drain water
flow.
Drain without Restrictor 3/4” MNPT
Required and Included: Brass Drain Line Flow Control Housing
(DLFC) with 7 GPM Flow Restrictor, 3/4” FNPT x 1/2” FNPT
Warning: Do not remove Drain Line Flow Control (DLFC). Re-
moval may cause media movement up into valve causing its
failure and/or into filtered water supply causing aethetic issues.
Electric
Set-Up and Installation Schematic for the following Units:
EWS-1354-HF; CWL-1354-HF
13”
Caution:
Due to system flow rate of 22 gpm and restricted drain flow of up to
7 gpm the valve during backwash is mechanically noisy. Do not be
alarmed. However check incoming line pressure not to exceed
65psi and any restricted drain line. You may re-set backwash for
daytime automatic cycle to avoid quieter evenings.
EWS & CWL 1354-HF
EWS/CWL-1354-HF
Service Line Size: 3/4” - 11/4”; Service Flow Rate: 22 gpm
Drain Line Size: min: 1/2”** (see proper specifications)
Installed Dimensions:
See diagrams for specific units
Dry Weight: 1354 - 165lbs.
Plumbing Clearances:
Minimum of 24” from front of unit to back wall for plumbing
Drain Flow: restricted up to 7 gpm (1354)
Factory Set: maximum of 18 minutes every 3rd day
Bypass needs to be plumbed for proper installation:
overall
height
63”