OS3030 Changing and Scanning the Basic Values
14. "Rinse during standby" phase
33
14. "Rinse during standby" phase
The “rinse during standby“ phase comprises three time-dependent stages
which run in consecutive order. If the rinse phase is over or interrupted and
the pressure pump is in operation, the system remains in its current position
for a further 3 seconds before the pump starts running.
You define whether the input valve and the concentrate valve are open
during these 3 stages, and when the pressure pump kicks in.
In the case of equipment with an IF plug-in card, you also specify whether
the output relay is activated for each of the output functions selected in pro-
gramming steps 6.1 and 6.2.
Program whether the
“rinse during standby
function has to be acti-
vated.
Specify the time lapse
between the final produc-
tion or rinse phase and
the switchover to this
rinse function. A gap of between 1 and 999 hours can be entered.
Set the time of the first
stage. The permissible
range is 0 to 9999 sec-
onds. If you select 0, the
stage is skipped.
Specify which valves are
open, whether the high-
pressure pump is running
and whether the pro-
grammed OUT1 and OUT2 outputs, if present, are active. The functions
programmed in programming steps 6.1 and 6.2 are active for these outputs.
Press INFO to see the meaning of the abbreviation in plain text.
PU = High-pressure pump PV = Permeate valve
IV = Input valve DO = Dosing
CV = Concentrate valve AP = Additional program
Set the time of the sec-
ond stage. The permissi-
ble range is 0 to 9999
seconds. If you select 0,
the stage is skipped..
Program the values in
accordance with pro-
gramming step 14.4.
Set the time of the third
stage. The permissible
range is 0 to 9999 sec-
onds. If you select 0, the
stage is skipped..
Program the values in
accordance with pro-
gramming step 14.4.
S t e p n o . : 1 4 . 1
R i n s e s t a n d b y Y
/ N
S t e p n o . : 1 4 . 2
D i s t a n c e 2 4 h
S t e p n o . : 1 4 . 3
R i n s e 1 5 s
S t e p n o . : 1 4 . 4
P U - I V | C V - P V - D O
-
S t e p n o . : 1 4 . 5
R i n s e 2 1 0 s
S t e p n o . : 1 4 . 6
P U - I V | C V | P V - D O
-
S t e p n o . : 1 4 . 7
R i n s e 3 3 0 0 s
S t e p n o . : 1 4 . 8
P U | I V | C V | P V - D O
-