EasyManua.ls Logo

EWS OS 3030 - Rinse During Production Phase Configuration; Rinse During Production Function Activation; Time Lapse Before Rinse During Production; Rinse During Production Stage Timing

Default Icon
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OS3030 Changing and scanning the basic settings
15. "Rinse during production" phase
34
HOURS
15. "Rinse during production" phase
The “rinse during production“ phase comprises three time-dependent stages
which run in consecutive order. If the rinse phase is over or interrupted and
the pressure pump is in operation, the system remains in its current position
for a further 3 seconds before the pump starts running.
You define whether the input valve and the concentrate valve are open during
these 3 stages, and when the pressure pump kicks in.
In the case of equipment with an IF plug-in card, you also specify whether the
output relay is activated for each of the output functions selected in pro-
gramming steps 6.1 and 6.2.
Program whether the "rinse
during production" phase
should be activated.
Specify the time lapse be-
tween the final production
or rinse phase and the
switchover to this rinse
function. A gap of between 1 and 999 hours can be entered.
Set the time of the first
stage. The permissible
range is 0 to 9999 sec-
onds. If you select 0, the
stage is skipped.
Specify which valves are
open, whether the high-
pressure pump is running
and whether the pro-
grammed OUT1 and OUT2 outputs, if present, are active. The functions pro-
grammed in programming steps 6.1 and 6.2 are active for these outputs.
Press INFO to see the meaning of the abbreviation in plain text.
PU = High-pressure pump PV = Permeate valve
IV = Input valve DO = Dosing
CV = Concentrate valve AP = Additional program
Set the time of the second
stage. The permissible
range is 0 to 9999 seconds.
If you select 0, the stage is
skipped.
Program the values in ac-
cordance with programming
step 15.4.
Set the time of the third
stage. The permissible
range is 0 to 9999 seconds.
If you select 0, the stage is
skipped.
Program the values in ac-
cordance with programming
step 15.4.
S t e p n o . : 1 5 . 2
D i s t a n c e 8 h
S t e p n o . : 1 5 . 1
R i n s e p r o d u c t Y
/ N
S t e p n o . : 1 5 . 3
R i n s e 1 2 0 s
S t e p n o . : 1 5 . 4
P U - I V | C V - P V - D O
-
S t e p n o . : 1 5 . 5
R i n s e 2 5 s
S t e p n o . : 1 5 . 6
P U - I V | C V | P V - D O
-
S t e p n o . : 1 5 . 7
R i n s e 3 1 0 0 s
S t e p n o . : 1 5 . 8
P U | I V | C V | P V - D O
-

Table of Contents

Related product manuals