EWS Series - 1354-HF Installation Schematics; 1354-HF Unit Schematics and Specs

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.2-12
www.EWSWATER.com office: 702-256-8182 (m-f; 8:30-4:30, pst) fax: 702-256-3744 customerservice@ewswater.com
Inlet (supply) Side
Bypass
Valve
Drain
High Flow DTV 2750 Valve, Cover: Black
NEMA 1 Rated: resists dust and moisture
Hinged: left, Controls: inside
Back Side: Front Side:
Materials Needed for Installation:
Inlet and Outlet on valve are both 1” MNPT
1” and 11/4” pipe length to be determined
Qty. 3 - 1” Ball Valves
Qty. 2 - 1” Unions
Qty. 1- Union for drain line** (see proper specifications)
Union
Union
Outlet (filtered)Side
inlet
1” MNPT
56 1/2”
on center
outlet
1” MNPT
58 1/2”
on center
drain
1/2” FNPT
57 1/2”
on center
Due to tank and base variances overall dimensions +/- 1”
Materials Needed for Drain:**
1/2” MNPT copper x 1/2” (min.) male adapter
1/2” (min.) union
1/2” (min.) drain line, pipe length to be determined
**Nominal drain line and drain size should be a minimum of
1/2”. Drain line exceeding 20’ in length and/or drain water that is
expected to flow over 5’ above the height of the drain port re-
quires a 3/4” line and drain. Install, non-restrictive, check valve
in drain line, if drain water is expected to flow over 5’ above the
height of the drain port . Never restrict the backwash drain water
flow.
Drain without Restrictor 3/4” MNPT
Required and Included: Brass Drain Line Flow Control Housing
(DLFC) with 7 GPM Flow Restrictor, 3/4” FNPT x 1/2” FNPT
Warning: Do not remove Drain Line Flow Control (DLFC). Re-
moval may cause media movement up into valve causing its
failure and/or into filtered water supply causing aethetic issues.
Electric
Set-Up and Installation Schematic for the following Units:
EWS-1354-HF; CWL-1354-HF
13”
Caution:
Due to system flow rate of 22 gpm and restricted drain flow of up to
7 gpm the valve during backwash is mechanically noisy. Do not be
alarmed. However check incoming line pressure not to exceed
65psi and any restricted drain line. You may re-set backwash for
daytime automatic cycle to avoid quieter evenings.
EWS & CWL 1354-HF
EWS/CWL-1354-HF
Service Line Size: 3/4” - 11/4”; Service Flow Rate: 22 gpm
Drain Line Size: min: 1/2”** (see proper specifications)
Installed Dimensions:
See diagrams for specific units
Dry Weight: 1354 - 165lbs.
Plumbing Clearances:
Minimum of 24” from front of unit to back wall for plumbing
Drain Flow: restricted up to 7 gpm (1354)
Factory Set: maximum of 18 minutes every 3rd day
Bypass needs to be plumbed for proper installation:
overall
height
63”