11 Installing BlackDiamond Series Modules
This chapter provides important safety information and correct installation procedures for the MSMs
and I/O modules in the BlackDiamond 8800 series switches, BlackDiamond 12800 series switches, and
BlackDiamond 10808 switches. All module types are hot-swappable.
The chapter includes the following sections:
Module Slot Assignments on page 173
Distinguishing a BlackDiamond 8800 or 12800 MSM from an I/O Module on page 174
Installing a BlackDiamond 8800 or 12800 Series Module on page 175
Connecting and Disconnecting Cables on the 10G4Ca Module on page 178
Installing a BlackDiamond 10808 Series Module on page 179
Installing a Backup MSM on page 182
Verifying the Module Installation on page 182
Removing a BlackDiamond 8800 or 12800 Series Module on page 183
Removing a BlackDiamond 10808 Series Module on page 184
BlackDiamond Series Blank Front Panels on page 185
NOTE
Read the information in this chapter thoroughly before you attempt to install or remove an 8800 series MSM or I/O
module.
CAUTION
Do not attempt to mix modules across Extreme Networks product lines. BlackDiamond 8800 series modules are for
use only in a BlackDiamond 8810 or 8806 switch. Blackdiamond 12800 series modules are for use only in a
BlackDiamond 12804 or 12802 switch. When a BlackDiamond switch is in use, ExtremeXOS software will not
recognize a module from a different product line.
Module Slot Assignments
The specific slot locations for I/O modules and MSMs in the chassis are as follows:
BlackDiamond 8810 switch:
Slots 1, 2, 3, 4, 7, 8, 9, and 10 must have I/O modules.
Slot 5/A must have an MSM.
Slot 6/B can have an MSM or I/O module.
BlackDiamond 8806 switch:
Slots 1, 2, 5, and 6 must have I/O modules.
Slot 3/A must have an MSM.
Slot 4/B can have an MSM or I/O module.