Installing Modules and Establishing Initial Management Access
BlackDiamond 8800 Series Switches Hardware Installation Guide
118
To disconnect a cable from a 10G4Ca module:
1 Holding the cable connector with one hand, press it against the module front panel as you use the
other hand to pull back evenly on the latch (Figure 76).
Figure 76: Disconnecting a cable from a 10G4Ca port
2 Make sure the latch is pulled into the fully disengaged position.
3 Pull the cable connector straight off the port connector.
Connecting and Disconnecting Cables on the
8900-G96T-c Module
The ports on the 8900-G96T-c module use MRJ21 connectors. To connect these ports:
1 Align the cable connector with the port connector and firmly press the cable connector into place.
2 Use a small straight-tip screwdriver to align and tighten the retaining screw at each end of the cable
connector.
Installing a Backup MSM
If you install a backup MSM, use the synchronize command to replicate all saved images and
configurations from the primary MSM to the backup MSM.
You are not prompted to synchronize the images and the configurations from the primary to the
backup. If not synchronized, the backup uses its image and the primary configuration. This
image/configuration mismatch will likely cause the switch to operate differently after failover.
Depending on the size and complexity of your network, you should install and configure a backup
MSM when network disruption will be minimal. You may need to reboot your switch after you use the
synchronize command.
BD_158A