EasyManua.ls Logo

Extreme Networks Extreme 7520 Series - Environmental Standards; 800 W Power Supplies Technical Specifications

Extreme Networks Extreme 7520 Series
117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Environmental Standards
Operating conditions 7520-48Y and 7520-48XT, AC/DC, front-to-
back: 0°C (32°F) to 50°C (122°F) at sea level;
0°C (32°F) to 40°C (104°F) up to 3000 m
(10,000 ft)
7520-48Y and 7520-48XT, AC/DC, back-to-
front: 0°C (32°F) to 45°C (113°F) at sea level;
0°C (32°F) 40°C (104°F) to up to 3000 m
(10,000 ft)
Humidity: 5% to 95%, non-condensing
Altitude: 0 to 3,000 meters (9,850 feet)
Operational shock (half sine): 98 m/s
2
(10 G), 11
ms, 9 shocks
Operational random vibration: 3 to 500 Hz at
1.5 G rms
Storage & transportation conditions
(packaged)
Storage temperature: -40°C to 70°C (-40°F to
158°F)
Storage and transportation humidity: 95%
maximum relative humidity, non-condensing
Humidity: 5% to 95%, non-condensing
Packaged shock (half sine): 180 m/s
2
(18 G), 6
ms, 600 shocks
Packaged sine vibration: 5 to 62 Hz at velocity
5 mm/s, 62 to 500 Hz at 0.2 G
Packaged random vibration: : 5 to 20 Hz at 1.0
ASD w/–3 dB/ oct. from 20 to 200 Hz 14 drops
minimum on sides and corners at 42 in (<15
kg box)
800 W Power Supplies Technical Specications
Four 800 W power supply units are available for use:
800W AC power supply - front-to-back airow (part no. XN-ACPWR-800W-F)
800W AC power supply - back-to-front airow (part no. XN-ACPWR-800W-R)
800W DC power supply - front-to-back airow (part no. XN-DCPWR-800W-F)
800W DC power supply - back-to-front airow (part no. XN-DCPWR-800W-R)