3. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg).
FIGURE 46 Attaching the rear brackets to the rack posts
1. Screws, 10-32 x 5/8-in., panhead Phillips 2. Retainer nuts, 10-32
Flush-rear (recessed) mounting
The ush-rear (recessed) mounting is similar to the ush-front mounting except that the brackets are reversed on the device.
CAUTION
The device must be turned o and disconnected from the fabric during this
procedure.
NOTE
The illustrations in the rack installation procedures show a 1U device, but the instructions are the same for a 2U device. The
illustrations in the rack installation procedures are for reference only and may not show the actual device.
Complete the following tasks to install the device in a four-post rack:
1. Attaching the front brackets to the rear of the device on page 70
2. Attaching the extensions to the front of the device on page 70
3. Installing the device in the rack on page 71
4. Attaching the rear brackets to the extensions at the front of the device on page 72
5. Attaching the rear brackets to the front rack posts on page 74
Installing the Universal Four-Post Rack Kit (XBR-R000296)
ExtremeSwitching VDX 6740 Hardware Installation Guide
9036108-00 69