14
FAAC MODEL 950 BM Door Operator
10. KP-CONTROLLER PROGRAMMING UNIT
The KP-Controller is used for selecting operational functions, as
well as adjusting and programming the 950 Series automatic doors.
Itisdividedintotwoparts:axedpartusedforsignallingof
operational functions by means of pushbuttons and relevant
signalling LEDs (Fig. 23 ref.A), and a removable part with LCD
display and selection buttons to access complete programming
(Fig. 23 ref.B).
The KP-Controller display can be used as a temporary
programming unit if the parameter “Keep settings” in the
ADVANCED MENU is set to ON: after all programming and
adjustments have been carried out, KP-Controller can be fully
removed because the settings remain stored on the 950MPS
control board.
If KP-Controller is installed without display, a cover is provided (Fig.
23 ref.C).
KP-Controller can be disabled by a combination of keys (see the
special LOCK function) or by internally installing a jumper that acts
as a switch (Fig. 24 ref. LOCK).
10.1. MOUNTING
RefertoFig.24foranexplodedviewofmounting;twoknockout
areas marked A and B are provided for entry of connection cable.
10.2 . CONNECTIONS
Connect the KP-Controller to the 950 I/O control board by a
2x0.5mm² max 50m cable (Fig. 24).
If the two LOCK terminals are connected to each other as shown in
Fig.24, all keys on the programmer are disabled.
10.3 . DIAGNOSTICS
The KP-Controller (also without display) has a diagnostic function
which, in case of an alarm, interrupts the normal display of the fun-
ction every 2 seconds in order to show the fault status for 1 second
byacombinationofashingLEDs.
Consult Fig. 25 and table 9 to identify the type of alarm according
totheashingLEDs.Intheeventofseveralsimultaneousfaults,
thecodeoffaultdetectedrstisdisplayed.
2x0.5 mm
2
max 50m
Fig. 24
A
B
Fig. 23
A
B
C
Table 9 DIAGNOSTICS Led =on = off
DESCRIPTION MEANING
3 FORCED OPEN Door forced opening in progress
7 EMERG. ON Emergency input active
9 OBST.INCLOS. Closingobstacledetected3successivetimes;Resetnecessarytorestoreoperation
10 v Lock locked in closed position
12 v Incorrect power supply to accessories (24Vdc absent)
15 v Setup not possibile
18 v Initialisation process not possible on motor: leaf stroke too long
20 v Initialisationprocessnotpossibleonmotor:insufcientleafstroke
22 v Leaf too heavy
24 v Motor failure
26 v 950 MPS control board failure
27 v No power supply
28 v Setup cycle required
29 v Encoder failure
30 v Driver motor failure
31 v EEPROM failure
32 v Master/Slave communication error
1
2 3 4 5 876
1
2
3
4
5
6
7
8
Fig. 25