15
FAAC MODEL 950 BM Door Operator
10.4 . OPERATIONAL FUNCTIONS
Selectionisperformedbypressingthekeysonthexedpartofthe
programmer - the function is indicated by the corresponding LED
lighting up.
Note: when the “Night” or “Manual” modes have been set, the rele-
vant selection keys must be pressed to exit the modes.
MANUAL
The door is free and can be activated manually.
BI-DIRECTIONAL
Pedestriantransitispossibleinbothdirections;theinsideand
outside radars are enabled.
ONE-WAY
Pedestriantransitispossibleinonedirectiononly;theexternal
radar is disabled.
PARTIAL OPENING
The door opens only partially (standard: 80%)
Partial opening can be adjusted in range from 60% to 90% of total.
TOTAL OPENING
The door opens completely.
AUTOMATIC
The door opens (partially or totally) and then re-closes after the set
pause time (standard: 2 sec.).
Pause time adjustment: form 0 to 30 sec.
DOOR OPEN
The door opens and stays open.
NIGHT
The door closes and the lock (if present) is activated. The internal
and external radars are disabled.
The Key command causes opening and closing after the night
pause time elapses (standard: 7 sec).
Adjusting range of night pause time: from 0 to 30 sec.
To obtain partial opening in this mode, before selecting the “Night”
function, activate the “Partial Opening” function.
10.5 . SPECIAL FUNCTIONS
SETUP
Setup is the door initialisation function during which parameters are
self-learned.
To activate, simultaneously press keys 1 and 5 for 5 sec.
RESET
Reset is the function for restoring normal operating conditions after
some types of alarm have been signalled.
To activate, simultaneously press keys 2 and 3.
LOCK
When active, the Lock function disables the KP-Controller.
To activate and de-activate, simultaneously press keys 3 and 4 for
5 sec.
10.6 . INSERTING AND CHANGING BATTERY
To keep the clock inside KP-Controller active even in the event
of a power failure, a 3V model CR1216 lithium battery has to be
installed.Toinsertorreplacethebattery,ndthecompartmenton
the printed circuit (Fig. 27) and follow the indicated polarity.
Fig. 27
Fig. 26
MANUAL
BI-DIRECTIONAL
ONE-WAY
PARTIAL OPENING
TOTAL OPENING
AUTOMATIC
DOOR OPEN
NIGHT
1
2
3
4
5
1
2 3 4
5