EasyManua.ls Logo

FAAC A1400 AIR RDT - 11.3 Mechanical Stop Adjustment

FAAC A1400 AIR RDT
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A1400 AIR RDT 46 532119 04 - Rev. C
58
1
1
1
5
2
Nm
59
2
60
1
5
2
Nm
1
2
Translation of the original instructions
ENGLISH
11.3 ADJUST THE MECHANICAL STOPS
!
The adjustment of the mechanical stops is indispensable for correct
operation of the automation.
The carriages must come into contact with the mechanical stops
positioned at stroke end in opening and closing.
STOPS ON OPENING
1. Loosen the 2 grub screws 58-
to release the mechanical stop.
2. Completely open the leaf 59-
.
3. Bring the mechanical stop pad and carriage into contact 59-
.
4. Tighten the 2 grub screws to lock the mechanical stop 58-
.
DOUBLE LEAF CLOSING STOPS
!
In double leaf automations, the leaves must close at the head sec-
tion centre line.
1. Move the leaves in the closed door position.
2. For each leaf, ensure the carriage is in full contact with the closing
stop pad.
Should adjustment be required:
3. Bring the mechanical stop pad and carriage into contact 59-
.
4. Tighten the 2 grub screws to lock the mechanical stop 58-
.
SINGLE LEAF CLOSING STOPS
With closed door the carriage must be in full contact with the me-
chanical stop.
1. Loosen the 2 grub screws to release the mechanical stop 58-
.
2. Close the leaf.
3. Bring the mechanical stop pad and carriage into contact 59-
.
4. Tighten the 2 grub screws to lock the mechanical stop 59-
.