Translation of the original instructions
ENGLISH
12.7 EXIT AND ENTRY DETECTORS XDT3
Use the exit detector XDT3 for opening and safety on closure, in
compliance with EN 16005:2012 and DIN18650.
!
It is recommended not to activate the “narrow pavement” function
which combines radar and infrared detection for opening.
Use the entry detector XDT3 for opening and safety on closure, in
compliance with EN 16005:2012 and DIN18650.
DEFAULT PROGRAMMING OF DETECTOR XDT3
Radar Output Configuration: Current
DEFAULT PROGRAMMING ON BOARD E1400 RD
Programming from board or SDK EVO:
From Board from SDK EVO
Id=
Y
Ed=
2
P4=
Cc
4F=
Y
P3=
Cc
3F=
Y
I/E Sensors
I Function = Internal Current
E Function =
External Current (Not DEFAULT)
Safeties S1-S4
S4 Function = Closing Safety
S4 Test = Enabled
S4 NO/NC = NC
S3 Function = Closing Safety
S3 Test = Enabled
S3 NO/NC = NC
yellow/black +
white/black -
XDT3 esterno
test output
safety
power supply
opening
outputs
emergency
brown
pink
red
blue
green
grey
!
ATTENTION: IT IS OBLIGATORY TO INSTALL PROTECTIVE BARRIERS IN
THE MOVEMENT AREAS IN THE EVENT CONTACT WITH PERSONS IS
NOT ALLOWED.
yellow black +
white black -
brown
pink
red
blue
green
grey
test output
safety
opening
outputs
emergency
power supply
XDT3
(internal)
XDT3 interno
XDT3
(external)
entry
outside of
door
inside of door
exit - escape route
outside of
door
inside of door
exit - escape route