Error Required action (perform RESET after the intervention)
1
Board failure Perform RESET. If the problem persists replace the control board.
2
Board E
2
prom fault Perform RESET. If the problem persists replace the control board.
3
Motor_1 Driver failure Perform RESET. If the problem persists replace the control board.
4
Faulty accessories power supply Perform RESET. If the problem persists replace the control board.
5
micro-controller error
Update FW. The file on USB storage device is required (78)
6
Motor_1 power supply voltage fault Perform RESET. If the problem persists replace the control board.
7
Motor_1 faulty Replace Motor_1.
8
Opening failed with AUX_Motor Perform RESET. If the problem persists replace the control board.
9
Mains power supply (V main) absent* The door performs opening with battery power supply and remains open in error (safety
condition)
Wait for the mains power supply to be restored
If the error persists despite mains power supply being on, replace the power supply unit.
10
Battery down or NOT connected* If the battery is down or disconnected, the door performs opening and remains open in error.
Check battery status and connection. If the battery is completely drained, the charging cycle
requires several hours. Perform reset.
11
S1 test failed
Check that:
- connection of the safety device.
- operation of the safety device.
- input programming
P1-
P2-
P3-
P4.
12
S2 test failed
13
S3 test failed
14
S4 test failed
15
Data in setup memory not present or corrupted Perform SETUP.
16
Encoder failure Replace Motor_1.
17
Inputs failure Perform RESET. If the problem persists replace the control board.
18
Firmware (FW) not compatible During the update stage, an incorrect FW has been detected. Check and update again the
control board FW. The file on USB storage device is required (78).
19
High mechanical friction Check the leaves slide smoothly with power supply, battery and motors disconnected. Remove
any friction. Check the counter wheel.
20
Inputs configured as safety devices test failed Check input connection and programming.
21
Opening speed low
Modify speed programming:
OS function.
SDK EVO also allows the acceleration and deceleration ramps and slow down space to be
modified in opening.
A SETUP must then be performed.
22
Corrupted data Perform board programming again, or upload programming files saved on USB memory
stick (78).
23
Power supply unit fault Replace power supply unit
24
Consecutive obstacles in closing Check for and remove the obstacle in closing. If the error persists with no obstacle check the
level of force in closing.
25
AUX_Motor faulty Replace Auxiliary_Motor.
26
Motor block fault Replace motor block
27
Motor_1 rotation error Check belt connection to the leaves.
28
AUX_Motor rotation error Check auxiliary_motor connection
29
_AUX board fault Replace the control board.
30
Serious error
(with continuous buzzer)
It is impossible to open with both motors. Set manual mode and manually open the leaves.
Request the installer's servicing.
31
Consecutive obstacles in opening Check for and remove the obstacle in opening.
39
Board data being deleted Restore procedure executed.
* When the condition is restored, this error disappears without requiring a RESET.