A1400 AIR RDT 92 532119 04 - Rev. C
Translation of the original instructions
ENGLISH
2 Partial opening
Defines the opening percentage in PARTIAL OPENING mode. The
default and interval of settings is:
- PARTIAL OPENING 100% (20-100)
3 AUX test time
Defines frequency (in hours) of the test on the Auxiliary_motor. The
default and interval of settings is:
- AUX TEST TIME 24 H (2-24)
4 Board Display
Enables/disables programming from the board. The options with
relevant default are as follows:
- Not
blocked (Default)
- Blocked
5 Safety Opening Function
Defines the safety in opening function
- STOP
- LOW ENERGY (slow speed motion) (Default)
6 Intrusion
Defines door behaviour in case of attempt to open manually. The
options
with relevant default are as follows:
- DISABLED does not actuate the motor (Default)
- KEEP CLOSED counter: the motor is actuated in closing
- PULL & GO the motor is actuated in opening
( NOT active with battery operation)
7 Partial Chemist’s Shop
It defines the opening percentage with the pharmacy control (only
active in NIGHT-TIME Mode). The default and interval of settings is:
- PARTIAL PHARMACY 20 % (1-95)
8 SDK EVO key
Defines function of key switch connected to SDK EVO (OPTIONAL
accessory):
- BLOCK (Default):
With NO (Normally Open) key switch, SDK EVO
it works normally. Password is required.
With NC (Normally Closed) key switch,SDK EVO it is blocked.
- WITHOUT USER PSW:
With NO (Normally Open) key switch, SDK EVO it works without
password.
With NC (Normally Closed) key switch,SDK EVO it works normally.
Password is required.
9 Consecutive obstacles
Defines the number of consecutive obstacles after which the door is
blocked in error. Choose and modify the parameter:
- CLOSING
from 0 to 3 (number of obstacles - default: 2)
- OPENING
from 1 to 3 (number of obstacles - default: 1)
The block due to obstacles in opening cannot be DISABLED.
■
7 INSTALLATION
OK
OK
INSTALLATION
2
PROGRAMMING
1 Number of leaves
Set the number of leaves of the system:
- 1 LEAF (Default)
- 2 LEAVES
2 Start SETUP
This command requires confirmation to perform SETUP.
!
Comply with the procedure on 63.
3 INPUT status
The display shows active inputs. In the example safety sensor S2 is on:
INPUT STATUS
IN4
S4
FSW2
OK
IN1
S1
INT
SM
IN2
S2
EXT
E1
IN3
S3
FSW1
E2
4 DOOR status
The display shows what status the door is in:
- CLOSED
- in OPENING
- OPENED
- in PAUSE
- in NIGHTTIME PAUSE
- in CLOSING
- EMERGENCY
- MANUAL MODE
- NIGHTTIME MODE
- AUX OPENING (opening with auxiliary_Motor)
- BOARD TEST
- STOP AND ERROR
- SECURITIES TEST
- ERROR
- SERIOUS ERROR
- SETUP IN PROGRESS
5 Other board data
The display reads:
- V_MAIN (input voltage to board in Volt)
- V_BATT (battery voltage in Volt)
- V_ACC (accessory voltage in Volt)
- I_MOT (current absorbed by the motor in Ampère)
- POS (leaf position in cm)
■
8 SUNDRIES
OK
OK
MISCELLANEUS
2
PROGRAMMING
1 Default Configuration
- ACTIVE (default configuration is present)
- NO (default configuration has been modified)
To reset all parameters to default settings press the OK button and
confirm.