EasyManua.ls Logo

FAAC A1400 AIR RDT - Menu 7 Timer Configuration (Continued); 4 Set Time Slot Start and End Times; Menu 8 Password Management; Installer Password Setup

FAAC A1400 AIR RDT
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A1400 AIR RDT 95 532119 04 - Rev. C
Translation of the original instructions
ENGLISH
4. Set time SLOT start and end time.
SLOT 1
ESC OK
START 00:00
END 00:00
5. Proceed in the same way for the other desired time SLOT.
6. In Auto Twodir Total mode, an example:
- SLOT 1 08:00-08:59 Open Total
- SLOT 2 09:00-09:59 Open Partial
- SLOT 3 11:00-11:59 Auto Out Total
- SLOT 4 12:00-12:01 Auto Out Partial
- SLOT 5 17:59-16:30 Auto Twodir Partial
- SLOT 6 22:00-23:59 Auto Twodir Total
9 Mon-Sun; 10 Mon-Fri
To quickly program groups of days of the week with the same time
SLOT:
1. Select the group of days (from Mon-Sun or from Mon-Fri).
2. Select the time SLOT.
3. Set time SLOT start and end time.
4. Assign the operating mode to the time SLOT. Repeat stages from
2 to 4 for any other time SLOT.
5. Apply programming to the group of days by selecting APPLY.
Confirm APPLY to apply the time SLOT to the set group days, any pre-
existing programming on individual days is overwritten.
11 JOLLY (WILD CARD)
To PROGRAM TIMER operation in JOLLY (WILD CARD) intervals (one
or more days that require different programming):
1. Select the JOLLY (WILD CARD) time SLOT.
JOLLY
ESC OK
- > SLOT1
- SLOT2
- SLOT3
- SLOT4
2. Assign an operating mode to the time SLOT:
- No Function (0)
- Auto Twodir Total (1)
- Auto Out Total (2)
- Auto Twodir Partial (3)
- Auto Out Partial (4)
- Open Total (5)
- Open Partial (6)
3. Set time SLOT start and end time
SLOT 1
ESC OK
START 01:00
END 23:00
4. Proceed in the same way for the other desired JOLLY (WILD CARD)
time SLOT.
12 JOLLY (WILD CARD) Intervals
To apply JOLLY (WILD CARD) programming to individual days or
intervals of days:
1. Enable an interval (max 6 JOLLY (WILD CARD) intervals).
2. Define the interval’s beginning and end date.
3. In Auto Twodir Total mode, a JOLLY (WILD CARD) example:
- SLOT 1 07:00-09:59 Auto Out Partial
- SLOT 2 10:00-10:01 Auto Out Total
- SLOT 3 10:30-11:00 Open Total
- SLOT 4 15:00-23:59 Open Partial
- SLOT 5 03:00-07:00 Auto Twodir Total
- SLOT 6 09:00-12:00 Auto Out Total
- Interval 1 25/12/2014 - 25/12/2014
- Interval 2 30/12/2014 - 31/12/2014
- Interval 3 01/01/2015 - 06/01/2015
- Interval 4 28/02/2015 - 01/03/2015
- Interval 5 30/04/2015 - 03/05/2015
- Interval 6 07/05/2015 - 09/06/2015
Should you wish to set an individual day, the interval beginning and
end date coincide.
The interval must refer to the year (e.g. the period from 25 December
to 6 January requires creating two intervals: one from 25/12 to 31/12
and the other from 01/01 to 06/01).
The TIMER makes it possible to override functions by means of time
SLOT from 0 to 6. The functions set from TIMER CANNOT be overwritten
by configured Inputs , SDK EVO or LKEVO.
TIMER active and with no time SLOT corresponds to function 0.
Exiting a time SLOT overrides function 1 modifiable by devices with
lower priority.
The priority order is as follows:
MANUAL
EMERGENCY
TIMER
Configured INPUTS
External programmers LKEVOand SDK EVO
MENU 8 PASSWORD
OK
OK
OK
8
TECHNICIAN PSW
OPERATOR PSW
PASSWORD
The Operator may ONLY edit the Operator password.
The installer may edit both passwords.
!
The personnel allowed to use the password to select the automation’s
operating modes must maintain password knowledge confidential.
INSTALLER PASSWORD
1. Enter the new PASSWORD and press OK.
2. The new PSW must be repeated and confirmed with OK:
If the PSW has not been repeated correctly, the display continues
requesting the new password and the confirmation.

Table of Contents