A1400 AIR RDT 95 532119 04 - Rev. C
Translation of the original instructions
ENGLISH
4. Set time SLOT start and end time.
SLOT 1
ESC ↑ ↓ OK
START 00:00
END 00:00
5. Proceed in the same way for the other desired time SLOT.
6. In Auto Twodir Total mode, an example:
- SLOT 1 08:00-08:59 Open Total
- SLOT 2 09:00-09:59 Open Partial
- SLOT 3 11:00-11:59 Auto Out Total
- SLOT 4 12:00-12:01 Auto Out Partial
- SLOT 5 17:59-16:30 Auto Twodir Partial
- SLOT 6 22:00-23:59 Auto Twodir Total
■
9 Mon-Sun; 10 Mon-Fri
To quickly program groups of days of the week with the same time
SLOT:
1. Select the group of days (from Mon-Sun or from Mon-Fri).
2. Select the time SLOT.
3. Set time SLOT start and end time.
4. Assign the operating mode to the time SLOT. Repeat stages from
2 to 4 for any other time SLOT.
5. Apply programming to the group of days by selecting APPLY.
Confirm APPLY to apply the time SLOT to the set group days, any pre-
existing programming on individual days is overwritten.
■
11 JOLLY (WILD CARD)
To PROGRAM TIMER operation in JOLLY (WILD CARD) intervals (one
or more days that require different programming):
1. Select the JOLLY (WILD CARD) time SLOT.
JOLLY
ESC ↑ ↓ OK
- > SLOT1
- SLOT2
- SLOT3
- SLOT4
2. Assign an operating mode to the time SLOT:
- No Function (0)
- Auto Twodir Total (1)
- Auto Out Total (2)
- Auto Twodir Partial (3)
- Auto Out Partial (4)
- Open Total (5)
- Open Partial (6)
3. Set time SLOT start and end time
SLOT 1
ESC ↑ ↓ OK
START 01:00
END 23:00
4. Proceed in the same way for the other desired JOLLY (WILD CARD)
time SLOT.
■
12 JOLLY (WILD CARD) Intervals
To apply JOLLY (WILD CARD) programming to individual days or
intervals of days:
1. Enable an interval (max 6 JOLLY (WILD CARD) intervals).
2. Define the interval’s beginning and end date.
3. In Auto Twodir Total mode, a JOLLY (WILD CARD) example:
- SLOT 1 07:00-09:59 Auto Out Partial
- SLOT 2 10:00-10:01 Auto Out Total
- SLOT 3 10:30-11:00 Open Total
- SLOT 4 15:00-23:59 Open Partial
- SLOT 5 03:00-07:00 Auto Twodir Total
- SLOT 6 09:00-12:00 Auto Out Total
- Interval 1 25/12/2014 - 25/12/2014
- Interval 2 30/12/2014 - 31/12/2014
- Interval 3 01/01/2015 - 06/01/2015
- Interval 4 28/02/2015 - 01/03/2015
- Interval 5 30/04/2015 - 03/05/2015
- Interval 6 07/05/2015 - 09/06/2015
Should you wish to set an individual day, the interval beginning and
end date coincide.
The interval must refer to the year (e.g. the period from 25 December
to 6 January requires creating two intervals: one from 25/12 to 31/12
and the other from 01/01 to 06/01).
The TIMER makes it possible to override functions by means of time
SLOT from 0 to 6. The functions set from TIMER CANNOT be overwritten
by configured Inputs , SDK EVO or LKEVO.
TIMER active and with no time SLOT corresponds to function 0.
Exiting a time SLOT overrides function 1 modifiable by devices with
lower priority.
The priority order is as follows:
MANUAL
EMERGENCY
TIMER
Configured INPUTS
External programmers LKEVOand SDK EVO
MENU 8 PASSWORD
OK
OK
OK
8
TECHNICIAN PSW
OPERATOR PSW
PASSWORD
The Operator may ONLY edit the Operator password.
The installer may edit both passwords.
!
The personnel allowed to use the password to select the automation’s
operating modes must maintain password knowledge confidential.
■
INSTALLER PASSWORD
1. Enter the new PASSWORD and press OK.
2. The new PSW must be repeated and confirmed with OK:
If the PSW has not been repeated correctly, the display continues
requesting the new password and the confirmation.