A1400 AIR 106 532129 04 - Rev.B
Translation of the original instructions
ENGLISH
- 9 Night-time
- 10 Partial night-time
- 11 Interlock
- 12 Interlock EXIT Only
- 13 Interlock Entry Only
3. Set time band start and end time
BAND 1
ESC OK
START 01:00
END 23:00
4. Proceed in the same way for the other desired Wild Card time bands.
12 WILD CARD Intervals
To apply Wild Card programming to individual days or intervals of days:
1. Enable an interval (max 6 Wild Card intervals).
2. Define the interval’s beginning and end date.
3. In Auto Twodir Total mode, a WILD CARD example:
- BAND 1 07:00-09:59 Auto Out Partial
- BAND 2 10:00-10:01 Auto Out Total
- BAND 3 10:30-11:00 Open Total
- BAND 4 15:00-23:59 Open Partial
- BAND 5 03:00-07:00 Auto Twodir Total
- BAND 6 09:00-12:00 Auto Out Total
- Interval 1 25/12/2014 - 25/12/2014
- Interval 2 30/12/2014 - 31/12/2014
- Interval 3 01/01/2015 - 06/01/2015
- Interval 4 28/02/2015 - 01/03/2015
- Interval 5 30/04/2015 - 03/05/2015
- Interval 6 07/05/2015 - 09/06/2015
Should you wish to set an individual day, the interval beginning and end
date coincide.
The interval must refer to same calendar year (e.g. for the period from
25
th
December to 6
th
January, create 2 intervals: from 25/12 to 31/12
and from 01/01 to 06/01).
Using the TIMER, functions can be overridden by means of time bands
from 0 to 6. The functions set from the TIMER CANNOT be overwritten by
SDK EVO or LK EVO configured inputs.
TIMER active and with no time band corresponds to function 0.
Exiting a time band overrides function 1 that can be modified by devices
having a lower priority.
The priority order is as follows:
MANUAL
EMERGENCY
TIMER
Configured INPUTS
External programmers LK EVO and SDK EVO
MENU 8 PASSWORD
OK
OK
OK
8
TECHNICIAN PSW
USER PSW
PASSWORD
The user is ONLY allowed to modify the user password.
The installer may edit both passwords.
!
The personnel allowed to use the password to select the automations
operating modes must maintain password knowledge confidential.
INSTALLER PASSWORD
1. Enter the new PASSWORD and press OK.
2. The new PSW must be repeated and confirmed with OK:
If the PSW has not been repeated correctly, the display continues request-
ing the new password and the confirmation.
ENTER INSTAL PSW
AGAIN
ESC OK
****
3. When the PSW has been repeated correctly, the display shows:
CHANGE INSTAL PSW
OK
NEW PSW ENTERED
USER PASSWORD
Proceed as with the INSTALLER PASSWORD menu.
MENU 9 INFO
OK
OK
OK
OK
OK
9
INFO
E1SL APP
VER.xx
E1SL BOOT
VER.xx
----, DM (*)
VER.xx
SDK EVO APP
VER.xx
The display shows the firmware versions of the control board and
installed devices.
(*) DM is only displayed if the DM KIT is used. If it is not present, the
field is empty.