DIP SWITCHES ON OFF FACTORY SETTING
1 Sensitivity high Sensitivity low (recommended ON
for mounting height < 2,2 m)
2 Passive mode Active mode OFF
3 Hold time : 2 sec Hold time : 0,5 sec OFF
A. MOUNTING THE BFP1
OPENING
AND
CLOSING
THE SENSOR
OPENING
AND
CLOSING
THE FSA
MOUNTING
THE SENSOR
Use a small screwdriver to open the sensor
Insert the screwdriver in the rectangular hole under the bracket cam
Use it as a lever upwards
Consider the position of the guide pin when inserting both legs of the
front cover to the base
Gently push both sides of the front cover
Insert the bottom of the front cover to the bottom clip of the base
Push on the top of the front cover face
Either use the screwdriver to open the FSA (left picture)
Or pinch off both sides of the front cover (right picture)
Rotate the front cover upwards
A.DIP SWITCHES SETTINGS AND RELAY CONFIGURATIONS
B.SENSING FIELD POSITION
ON
2
1
3
SETTING
OF
THE SENSOR
ACTIVEMODE PASSIVEMODE
DETECTION
NO DETECTION
DESCRIPTION
OF
THE PRODUCT
AND
THE SENSOR
Wiring
Inner view of the sensor front cover
Description of the product
Description of the sensor
12-24 V AC/DC
COM NO NC
1 2 3 4 5
OPENING THE
FSA ACCESSORY
CLOSING THE FSA ACCESSORY
The LED flashes for a few seconds when the sensor is switched on
The LED lights up through the lens when the sensor detects motion
The relay configurations are :
LED
SIGNAL
2,2 m
50 cm 50 cm 50 cm
1,5 m depth
3 m
PROFILE VIEW
2,2 m
50 cm 50 cm 50 cm 50 cm 50 cm
2,5 m
2,5 m
height 2,2 m
door
threshold
3 m
1,5 m
FRONT VIEW
FLAT VIEW
Stick the template on the wall
Drill the 2 holes to fix the FSA
and the hole for the cable
Open the FSA (see page 2 :
opening and closing the FSA
Accessory)
Cut the wire opening footprint
of the base
Fix the sensor to the FSA base
with the 2 screws
Connect the sensor to the cable
Close the FSA (see page 2 :
opening and closing the FSA
Accessory)
Wire Opening Footprints
Main cable
Unplug 5-wire connector
2 screws to fix the BFP1
2 brackets
Lens
2 screws to fix the brackets with
the BFP1
Masking Lens (2 units)
Microprocessor
LED
Dip Switches
PYRO element
Guide Pins of the BFP1 base
Guide pins of the BFP1 base
Guide pins of the masking lens
COM (3)
NO (4)
NC (5)
COM (3)
NO (4)
NC (5)
COM (3)
NO (4)
NC (5)
COM (3)
NO (4)
NC (5)
ACCESSORY