1
2
0
1
2
1
2
0
1
2
3
3
0
1
2
1
2
0
1
2
3
3
«click»
1
1
H
W
H
W
2 m
1 m
max.
5 cm
max. 5 cm
+
-
+
-
MOUNTING & WIRING
INFRARED FIELD - SAFETY
GREEN
BROWN
YELLOW
WHITE
PINK
GREY
RED
2
BLUE
2
POWER SUPPLY
OPENING INPUT
SAFETY INPUT
TEST
OUTPUT
WIDTH
RED
LED
1
Output status when sensor is operational
2
For compliance with EN 16005, connection
to door controller test output is required.
The door control unit and the door cover profi le must be correctly earthed.
SENSOR
H W
2.20 m 2.30 m
2.50 m 2.55 m
3.00 m 2.80 m
H W
2.20 m 1.20 m
2.50 m 1.40 m
3.00 m 1.60 m
Depth of curtain: 8-10 cm
Depth of safety fi eld: 25 cm*
RELAY R1
RELAY R2
12-30 V DC
Check position of IR-curtains with
Spotfi nder and adjust if necessary.
DOOR
Detection fi eld width indicated according to conditions defi ned in EN 16005 and including dimension of test body CA.
Available as accessory
ANGLE
CLOSER
AWAY
ORANGE
* in standard presetting
The size of the detection fi eld varies according to the mounting height of the sensor.
3
4
+
+
A
B
Launch an ASSISTED SETUP to verify wiring, position of the
curtains and correct functioning of the sensor.
SETTINGS (by DIP-switch)
QUICK SETUP
ASSISTED SETUP
SETUP
OPEN+CLOSE
RED-GREEN
OFF
RED-GREEN
OFF
Step outside of the detection fi eld before launching a setup.
LONG (> 3s)
LONG
SHORT
standard
critical
environment
standard
extreme
1
1
Enhanced IR-immunity which excludes EN 16005-conformity of the door. system.
LONG (> 3s)
critical environment: enhanced immunity for critical environments (rain, snow, lamps...). Only 1 IR-curtain activated.
standard: standard environments (factory setting)
NC
NO
The yellow and white wires have to be connected to launch an
assisted setup.
After changing a DIP-switch, the orange LED fl ashes.
A LONG push on the push button confi rms the setting.
Always launch a setup after changes of the DIP-settings.
- Test the good functioning of the installation before leaving the premises.
- The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery
directive 2006/42/EC.
- The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer
of the sensor.
- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
- Only trained and qualifi ed personnel may install and setup the sensor.
- The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
- Avoid touching any electronic and optical components, avoid vibrations, do not cover the sensor and avoid proximity to
neon lamps or moving objects.
- It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.
SAFETY INSTRUCTIONS
PRESETTINGS
ENVIRONMENT R2 CONFIGURATIONFREQUENCY
ORANGE OFF