7
EN
How do you install your oven?
Monophase 20A Meter
220-240 V ~ 50 Hz
Electrical outlet
2-prong receptacle
+ ground lead
IEC Standard 60083
Monophase line 220-240 V ~
Electrical connection
Power cable
length:
approximately 1.5 m
16A fuse or differential
circuit breaker
Before making the connection, ensure that the wires in your
electrical set-up have enough cross-sectional area to properly
supply electricity to the appliance (cross-sectional area must be
at least equal to that of the power cable).
The fuse in your set-up must be 16 amperes.
The electrical connection should be performed before the appliance is installed in the
cabinet.
The oven must be connected with a power cable (standardised) with three 1.5 mm
2
conductors (1 ph +1 N + ground) that must be connected to a monophase 220-240
V network via a IEC 60083 standardised receptacle (1 ph +1 N + ground lead) or an
all-pole cut-off device with a minimum distance between contact openings of 3 mm.
The safety wire (green-yellow) is connected to the appliance's terminal and must
be connected to the ground lead of the electrical set-up.
In the case of connections with an electric receptacle, it must remain accessible
after installation of the appliance.
The oven's neutral conductor (blue wire) must be connected to the network's
neutral conductor.