EN 10
if there are perceptible changes of gas pressure in the gas supply system, the simmering
flame should be set at the low pressure in the system to prevent the burner from
extinguishing during normal use.
after adjusting the taps put the knob back in its position and turn off the flame.
Fig. 10
CONNECTING THE HOB TO THE MAINS
The appliance is supplied with the mains cable without a plug.
Note:
1. The plug should be connected to the mains cable only by a properly certified
installer- electrician.
2. The mains socket should be easily accessible to the user.
3. Please make sure that feed cable does not touch hot burners when the hob is
working.
The hob is adjusted to alternating cur-rent
230V, 50Hz, and should be connected to the
mains socket equipped with properly
connected ground contact.
Connecting the hob to a socket without the
ground contact causes a danger of electric
shock in the even of a failure of the hob's
electric system
Fig.11