EN 16
Table 3
Symptoms Cause What to do
Not clear burner ports
- Close burners’ taps
- Close the shut-off valve on the system, before the hob
- Air the room
- Remove the elements of the burner, clean them and
clear the burner ports
- Assembly the burner correctly and try to light it again
The burner
does not light
Blocked (flooded )
nozzle
- Remove all the elements of the burner
- Clean the nozzle and, if necessary, use a thin copper
wire (do not use steel wire or drill the hole )
A break in the electric
system
- check the fuses- if any fuse is burnt, replace it
The igniter does
not light the
burner (no
spark)
Dirty burners and/or
ignitors
- clean and dry the burners and ignitors thoroughly
Note:
1. If after the above-specified steps have been taken the appliance still does not
work properly, contact the nearest authorised servicing company.
2. A faulty gas hob should not be used until it is repaired by qualified servicing
personnel.
3. If the appliance is not going to be used for a longer time period, clean it
thoroughly, close the valve before the hob and pull the feed cable plug from the
mains socket.