Installation manual
CNC 8035
MACHINE PARAMETERS
Ethernet parameters
4.
(SOFT M: V15.3X)
(S
OFT T: V16.3X)
·167·
DNCEACT (P22)
Not being used.
IPTYPE (P23)
Reserved. It must be set to "0".
DIRIP (P24)
CNC's IP address.
NETMASK (P25)
Network mask.
IPGATWAY(P26)
Gateway IP address.
IPWDNC (P27)
WinDNC server's IP address.
The WinDNC server is the external device to connect with via DNC. This device may be a CNC,
or a PC with WinDNC.
Defining it as 0.0.0.0 does not allow transferring from the CNC, but it is possible from the PC.
IPSNFS (P28) DIRNFS (P29)
Not being used.
MACID (P30)
Reserved. It must be set to "0".
Possible values
Four numbers between 0 and 255 separated by dots.
Default value: 0.0.0.0 (the network is not activated)
Possible values
Four numbers between 0 and 255 separated by dots.
Default value: 0.0.0.0 (the network is not activated)
Possible values
Four numbers between 0 and 255 separated by dots.
Default value: 0.0.0.0 (it has no gateway)
Possible values
Four numbers between 0 and 255 separated by dots.
Default value: 0.0.0.0