·61·
CNC 8035
(SOFT M: V15.3X)
(S
OFT T: V16.3X)
3
MACHINE AND POWER
CONNECTION
Mains connection of the central unit
The "Central Unit + Monitor" set has a three-prong male Phoenix connector with a 7.62 mm pitch.
Use an independent external power supply with the following specifications:
The central unit has a protection against overvoltage that activates at 36 V.
The supply current has the following shape on power-up:
Machine connection
The machine-tool must have all the interference generating elements (relay coils, contactors,
motors, etc.) uncoupled.
• DC relay coils.
Power switch.
• This power switch must be mounted in such a way that it is easily accessed and
at a distance between 0.7 meters (27.5 inches) and 1.7 meters (5.5ft) off the floor.
Install this unit in the proper place.
• It is recommended, whenever possible, to install the CNC away from coolants,
chemical product, blows, etc. that could damage it.
Pin Signal and function
1 + 24 V Power supply.
2 0 V Power supply.
3 Chassis Shield.
Nominal voltage 20 V minimum 30 V maximum
Ripple: 4 V
Nominal current: 2 A
Current peak on power-up: 8 A