·61·
CNC 8035
(SOFT M: V15.3X)
(S
OFT T: V16.3X)
3
MACHINE AND POWER
CONNECTION
Mains connection of the central unit
The "Central Unit + Monitor" set has a three-prong male Phoenix connector with a 7.62 mm pitch.
Use an independent external power supply with the following specifications:
The central unit has a protection against overvoltage that activates at 36 V.
The supply current has the following shape on power-up:
Machine connection
The machine-tool must have all the interference generating elements (relay coils, contactors,
motors, etc.) uncoupled.
DC relay coils.
Power switch.
This power switch must be mounted in such a way that it is easily accessed and
at a distance between 0.7 meters (27.5 inches) and 1.7 meters (5.5ft) off the floor.
Install this unit in the proper place.
It is recommended, whenever possible, to install the CNC away from coolants,
chemical product, blows, etc. that could damage it.
Pin Signal and function
1 + 24 V Power supply.
2 0 V Power supply.
3 Chassis Shield.
Nominal voltage 20 V minimum 30 V maximum
Ripple: 4 V
Nominal current: 2 A
Current peak on power-up: 8 A

Table of Contents