ForCustomerService:Call1‐866‐GOFAGOR–www.fagorcommercial.com|
P.8
REQUESTEDQUALITYOFTHEWATER
‐Hardness:5‐10ºF
‐Conductivity200‐2000µS
‐pH6.5–7.5
‐Chloride’sconcentration<150mg/litre
‐Chlorine0.2‐0.5mg/litre
‐Impurities<0,08mm
Itisnecessarytoremoveallforeigndebrisfromthewaterlinethatmaypotentiallygettrappedinthevalves
or
causeanobstruction,priortoconnectingtothemachine.
Useonlythesuppliedhoses(3/4”Femalehoseconnector)atthewaterconnections.Failuretodosomay
resultindamagetothesolenoidvalvethreadsandleaking.Tightenbyhand.Connectthebentsideofthehose
tothemachine.Adaptor
suppliedfor¾”femalegardenhoseconnection.
FORHARDWATERSUPPLIESWITHAHARDNESSOFOVER2GRAINSOR10ºFANDPHBEYONDTHERANGE
OF7.0–8.5,AWATERCONDITIONERMUSTBEINSTALLED.
Slowlyturnonthewatersupplytothemachineaftertheincomingfilllineand
thedrainlinehavebeen
installed.Checkforanyleaksandrepairasrequired.Allleaksmustberepairedpriortoplacingthemachinein
operation.
WATERDRAINAGEINSTALLATION
AttachthedrainhoseasshowninFig.5.Itisrecommendedtoaffixasiphonpipetopreventodors.All
pipingfromthemachinetothedrainmustbeaminimum1‐1/2”I.P.S.Thereshouldalsobeanairgapbetween
themachinedrainlineandthedrain.
Fornaturaloverflowefficiencyusefloordrain.
Fig.5
2
3
/
8
"
D=Drainhose
C=Draincollector
A=AirGap
F=ScrapBasket