ForCustomerService:Call1866GOFAGORwww.fagorcommercial.com|
P.15
DRAININGANDCLEANING
DrainingmustoccurEVERYDAYandifinahighapplication;itshouldbedrainedaftereachmealrush!
DrainingtheMachine
OpenthedoorandremovetheFrontRightS/SFilter,leavedooropen.(Fig.8)
Removetheoverflowtubebyinsertingafingerintothetopofthetube.(Fig.9)
DONOTREMOVESCRAPBASKET!DONOTLOOSEO’RINGFROMOVERFLOWTUBE!
Pressandholdthebutton
P1(3)for5seconds(Fig.9).Thelednumber4willilluminateduring
operation
Waituntiltheled(3)turnsoff.(3minutes20seconds)
Takeoutscrapbasketforcleaningbytwistingtotheleft.(Fig.10)
Replacescrapbasket,lockintopositionbytwisting
totherightandreplaceoverflowtubewith
Oring.
ReplaceS/Sfilterbackintoposition.(Fig.8)
Presspowerswitch(1)toturnunitOFF
Toavoidtheriskofdamagefromoxidizationorcorrosionfromchemicals,keepallsteelsurfacescleanand
dry.Itisadvisabletochangethetankwater,bynewfilling,atleastevery4050washesortwiceaday.
Fig.7
AD48W/AD64CW/AD72W