SERVICE MANUAL
EVO FRONT LOADING DISHWASHER
• The gases leaving the fluepipe are at high temperatures and may cause burns. Do NOT obstruct the fluepipe
output.
7.2. LEVELLING
The appliances have adjustable legs to ensure they are correctly levelled. Turn the leg to obtain the required height.
The flooring on which the appliance is to be installed must be able to bear its full weight.
For optimum operation, it is essential that the appliance is correctly levelled.
Fagor Industrial recommends that the place where the appliance is to be installed should
be analysed prior to installation to check that it is suitable. The installation location must
be able to withstand the weight of the appliance.
Electrical cables, water and drainage hoses must not be trapped or contain kinks.
Turn the leg clockwise to extend and anticlockwise to shorten.
The installation of this appliance requires electrical and hydraulic connections, and an
adequate ventilation/extraction system due to the steam emitted by the machine.
8. CONNECTIONS
8.1. ELECTRICAL CONNECTION
Before connecting the machine to the power connection, check that the network voltage and frequency correspond
to those indicated on the appliance nameplate. Check that the cross-section of the power cable is appropriate for
the required consumption.
It is essential that the electrical installation where it is going to be connected has an EARTHING SOCKET, in
addition to the appropriate protection of the magneto-thermal switch and differential.
An AUTHORISED TECHNICIAN should always carry out the appliance’s electrical connection.
The legal standards in force in each country on connections to the mains should be taken into account.
• The specifications plate indicates the maximum power in kilowatts (kW) and amperes (A) for the correct
sizing of the installation components (line, power supply cable…). If the configuration is changed, the
values must be revised.
• Check that the mains voltage corresponds to that indicated on the appliance nameplate.
• The electric cable should be flexible, with an oil-proof covering, and it should not weigh less than the cable
in an ordinary sleeve made of standard polychloroprene or an equivalent synthetic elastomer (H05RN-F or
H07RN-F).
• The cross-section of the power cable must be suitable for the rated current of the machine.
• The machine must be connected to earth using the connection on the machine connection strip.
• The manufacturer will not be held liable for damage originated by failure to observe this requirement.
• Near the appliance and easily accessible to the user, between the power supply and the appliance, a