EasyManua.ls Logo

Fagor AD-64CW - Water Quality and Drainage

Fagor AD-64CW
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ForCustomerService:Call1866GOFAGORwww.fagorcommercial.com|
P.8
REQUESTEDQUALITYOFTHEWATER
Hardness:510ºF
Conductivity2002000µS
pH6.57.5
Chloride’sconcentration<150mg/litre
Chlorine0.20.5mg/litre
Impurities<0,08mm
Itisnecessarytoremoveallforeigndebrisfromthewaterlinethatmaypotentiallygettrappedinthevalves
or
causeanobstruction,priortoconnectingtothemachine.
Useonlythesuppliedhoses(3/4”Femalehoseconnector)atthewaterconnections.Failuretodosomay
resultindamagetothesolenoidvalvethreadsandleaking.Tightenbyhand.Connectthebentsideofthehose
tothemachine.Adaptor
suppliedfor¾”femalegardenhoseconnection.
FORHARDWATERSUPPLIESWITHAHARDNESSOFOVER2GRAINSOR10ºFANDPHBEYONDTHERANGE
OF7.08.5,AWATERCONDITIONERMUSTBEINSTALLED.
Slowlyturnonthewatersupplytothemachineaftertheincomingfilllineand
thedrainlinehavebeen
installed.Checkforanyleaksandrepairasrequired.Allleaksmustberepairedpriortoplacingthemachinein
operation.
WATERDRAINAGEINSTALLATION
AttachthedrainhoseasshowninFig.5.Itisrecommendedtoaffixasiphonpipetopreventodors.All
pipingfromthemachinetothedrainmustbeaminimum11/2”I.P.S.Thereshouldalsobeanairgapbetween
themachinedrainlineandthedrain.
Fornaturaloverflowefficiencyusefloordrain.
Fig.5
2
3
/
8
"
D=Drainhose
C=Draincollector
A=AirGap
F=ScrapBasket

Related product manuals