79
In model 0623, the installation (Fig.15.) should be in such
a way as to ensure that the installed drainage outlet is
below the oven outlet with a suitable slope to ensure
drainage (>5% or 3º).
Use DN40 PVC piping without reductions for the installation.
A drainage syphon is not required as this is built into the
oven.
Fig. 13: Table top models 061-101-102
Fig. 14: Desktop model 201 and 202
Once the drainage KIT has been installed, the discharge to the general drainage must be via a type
`AA`, `AB` or `AD` air gap in accordance with EN 1717.