In the new ADVANCE
ADVANCEADVANCE
ADVANCE oven, the spark is generated (by a spark generator Ref.
Ref. Ref.
Ref. SAP 12039544 for all the GAS RANGE
SAP 12039544 for all the GAS RANGESAP 12039544 for all the GAS RANGE
SAP 12039544 for all the GAS RANGE)
between the spark plug and a rod which acts as an EARTH
EARTHEARTH
EARTH (See attached figure)
To ensure correct operation and to avoid minor “explosions“ due to incorrect ignitions, and the locking of the system, it is
essential to check the following measures are taken:
• Distance between flame detector - burner “ A “ – 7 mm
• Distance between spark plug – earth “ B “ – 4 mm
• Distance between spark plug – burner “ C “ – 7 mm
BURNER POWERS AND SAP REFERENCES:
BURNER POWERS AND SAP REFERENCES:BURNER POWERS AND SAP REFERENCES:
BURNER POWERS AND SAP REFERENCES:
CONVECTION burner (BUTANE PROPANE)
STEAM GENERATOR burner (BUTANE PROPANE)
MODEL SAP CODE TOTAL POWER
61 12039583
101
12039583
102
12044278
201
12044424
202
12039427
MODEL SAP CODE TOTAL POWER
61 12039680 12 KW
12039442
201
12039556 X 2