SERVICE MANUAL
ADVANCE OVENS
04/02/2020 100
Convection
Mixed
Regeneration
Controlled steam
Steam
Range [20÷300] ºC
Range [20÷250] ºC
Range [20÷180] ºC
Range [35÷125] ºC
Range [99 ºC]
160 ºC (default
setting)
140 ºC (default
setting)
120 ºC (default
setting)
80 ºC (default
setting)
99 ºC (default
setting)
o True temperature of the chamber (Left-hand number). Shows True Temperature of the oven (given by
the chamber probe). The true temperature range is from -5÷330 ºC. An error is displayed if the probe
indicates a value outside the established range.
o Temperature Setting in chamber (Right-hand number) Shows chamber Temperature selected by the
user.
16.8. TIME SELECTION
To select the time function, press Function Selector. All the options are lit and the selected option flashes. Turn the
General Option Knob to change the selection and select the Time option. To confirm the selected option, press
either the Function Selector button or the Main Selector.
Select the cooking time by pressing the Time Selector and turning the Main Selector until the required time is
obtained. Confirm this value by pressing the Time Selector again or the General Option Knob.
When the time reaches 0, the number starts to flash, the horn is heard and the light flashes in time with the horn
until the door is opened or for a maximum of 30 seconds. If the door is not opened, the acoustic/visual warning is
repeated for 30 seconds every 3 minutes.
Time remaining (Left-hand number) This shows the time remaining in hours and minutes until the
selected cooking mode is completed. The time deceases every minute. The time is displayed as
follows: HH:MM.
When the time reaches 0 the buzzer is heard until the button on the wheel or the START/STOP button is
pressed, the door is opened or after 30 seconds If the door is not opened, or if the button on the wheel
or the START/STOP button is not pressed, the acoustic/visual warning is repeated for 30 seconds every
3 minutes. When the door is opened or either of the 2 buttons is pressed, the remaining time is
automatically re-established, loading the stipulated times.
Time setting (Right-hand number) Time setting selected by the user. The maximum selection time is 19
hours and 59 minutes.
If the oven is on and the time setting is changed, the remaining time will vary in the same proportion as
the temperature setting is increased / decreased.
If it is decreased while the value is at 0, it switches to indefinite mode first and then to preheating mode.
If the latter mode is entered (by pressing the START/STOP, the oven is preheated to the setting
temperature and the buzzer is heard (30
every 3) when the established temperature is reached.
16.9. PRICK PROBE FUNCTION
To select the function, press Function Selector. All the options are lit and the selected option flashes. Turn the
General Option Knob to change the selection and select the Core Spike Probe option. To confirm the selected
option, press either the Function Selector or the General Option Knob.
When the Core Spike Probe function has been selected, insert the spike into the food and close the oven.
The Time Setting display indicates the Set temperature selected for the core of the product to be cooked. To
change it, press Time Setting, Spike and Delta Probe Selector and change the value using the General Selector.
To confirm the new temperature value for the core spike probe function, press the Time Setting, Spike and Delta
Probe Selector or the General Selector.
The Time remaining display indicates the True temperature at the core of the food.
To select the oven temperature, press the Temperature setting selector and select the required temperature by
turning the General Option Knob. Confirm the temperature by pressing the Time Setting, Spike and Delta Probe
Selector or the General Selector.
The True Temperature display indicates the True Temperature of the oven.
Next select the cooking mode as described in the previous paragraph.
After selecting the parameters, press the START/STOP button and the oven starts to work.
The range of temperatures available in core spike probe mode are as follows: