16.23. SETTINGS (OVEN CONFIGURATION)
This function is protected by a password, which can be accessed by pressing the buttons Configure System and
Delayed Programming for 5 seconds while the oven is switched off. I.e, in OFF
mode. Password 7455.
Use the wheel to move through this menu.
The sections and respective options are as follows:
M34 Reset Oven
o M74 Counters All the stored log counters are reset.
o M75 Errors Resets any errors to date.
o M76 Parameters: Restore the factory default values established for the oven.
Temperature scale (ºC)
Delta value (50)
Thermal stop (No)
Model (201)
Oven type (Elec)
Gas type (BP)
Blower Speed Blowers (see table of speeds)
Condensation (2)
Automatic drainage (24)
M35 Configure (Configuration)
o M43 Oven Model Configure oven size
061
101
201 (default setting)
102
202
o M44 Oven type Allows you to configure oven as electric or gas.
M55 Electric (default setting)
M56 Gas
o M45 Gas Type Selection of gas type (only if the oven has been configured as Gas)
M57 Butane-Propane (Default setting)
M58 Natural Gas
M59 City Gas
o M47 Blower Sp. Allows you to change the different blower speeds. The increase in speed is in fractions of
100 (only if the oven has been configured as Gas)
The default setting for each operating mode is determined by the oven model and the type of gas selected
VCC (convection blower)
o M80 On Start-up speed (0 ÷ 8000)
o M81 Maximum Minimum speed (0 ÷ 8000)
o M82 Medium Maximum speed (0 ÷ 8000)
VCV (steam blower)
o M80 On Start-up speed (0 ÷ 8000)
o M81 Maximum Minimum speed (0 ÷ 8000)
o M82 Medium Maximum speed (0 ÷ 8000)
o M48 Condensat Option for configuring the condensation cycle.. It is possible to select how long the
condensation is required to be active for every 10 seconds of the cycle.