SERVICE MANUAL
ADVANCE OVENS
04/02/2020 107
0 ÷ 10 (Default setting: 2 seconds)
TABLE OF DEFAULT CONVECTION BLOWER SPEEDS
NATURAL GAS
TOWN GAS
LGP (B/P)
AG-061
Start-up: 4000
Medium: 4200
Maximum: 6500
Start-up: 4000
Medium: 4200
Maximum: 6500
Start-up: 4000
Medium: 3600
Maximum: 5400
AG-101
Start-up Speed: 5000
Medium: 4000
Maximum: 7500
Start-up: 5000
Medium: 4000
Maximum: 7500
Start-up: 5000
Medium: 3600
Maximum: 6000
AG-201
Start-up: 4000
Medium: 4200
Maximum: 8000
Start-up: 4000
Medium: 4000
Maximum: 7200
Start-up: 4000
Medium: 3800
Maximum: 6200
AG-102
Start-up: 4000
Medium: 4000
Maximum: 8000
Start-up: 4000
Medium: 4000
Maximum: 8000
Start-up: 4000
Medium: 3500
Maximum: 6100
AG-202
Start-up: 4000
Medium: 3800
Maximum: 8000
Start-up: 4000
Medium: 4200
Maximum: 8000
Start-up: 4000
Medium: 3500
Maximum: 6000
TABLE OF DEFAULT STEAM BLOWER SPEEDS
NATURAL GAS
TOWN GAS
LGP (B/P)
AG-061
Start-up: 4000
Medium: Tg>90ºC, -
15%Max
Maximum: 5000
Start-up: 4000
Medium: 5000
Maximum: 5000
Start-up: 4000
Medium: Tg>90ºC, -
15%Max
Maximum: 4300
AG-101
Start-up Speed: 5000
Medium: Tg>90ºC, -
15%Max
Maximum: 6400
Start-up: 5000
Medium: 6600
Maximum: 6600
Start-up: 5000
Medium: Tg>90ºC, -
15%Max
Maximum: 5700
AG-201
Start-up: 4000
Medium: Tg>90ºC, -
15%Max
Maximum: 6700
Start-up: 4000
Medium: 6200
Maximum: 6200
Start-up: 4000
Medium: Tg>90ºC, -
15%Max
Maximum: 5500
AG-102
Start-up: 5500
Medium: Tg>90ºC, -
15%Max
Maximum: 6200
Start-up: 4000
Medium: 6200
Maximum: 6200
Start-up: 4000
Medium: Tg>90ºC, -
15%Max
Maximum: 5300
AG-202
Start-up: 4000
Medium: Tg>90ºC, -
15%Max
Maximum: 7300
Start-up: 4000
Medium: 8000
Maximum: 8000
Start-up: 4000
Medium: Tg>90ºC, -
15%Max
Maximum: 6000
o M49 Auto. Auto Permits the configuration of the frequency with which the oven should drain the boiler, that
is, every so many hours of the oven
s operation (all modes except convection, where TG > 60 ºC) the
drainage cycle must be run.
1 ÷ 63 hours (Default setting: 24 hours)
M68 Draining This message is displayed when the appliance is draining.
M69 Max Level This message is displayed when, during the drainage cycle, the level detecting rods
detect maximum level.
M70 Min Level This message is displayed when, during the drainage cycle, the level detecting rods detect
minimum level.
M71 Below Min This message is displayed when, during the drainage cycle, the level detecting rods
detect the level is below the minimum.
M72 End Drainage This message is displayed when the drainage cycle is completed.