SERVICE MANUAL
ADVANCE OVENS
04/02/2020 109
o Resistance NTC
o Door contactor IP
o Maximum level probe MAX
o Minimum level probe MIN
o Gas control signal HALL. To read the burner blower input, first activate the PWM output
with the blower speed selected. (only in gas ovens).
Outputs for testing
o Chamber heating (CC1)
o Chamber heating (CC2)
o Fan on M/P
o Fan direction L/R
o Condensation electrovalve (VCN)
o Humidification electrovalve (VHM)
o Chimney motor (Ms/Mb)
o Main supply relay (RG)
o Fan (VE)
o Oven lighting (LZ)
o Drainage pump (VAC)
o Water inlet solenoid valve (VDV)
o Steam heating (CV1)
o Steam heating (CV2)
Warning bell (TA)
M39 Reliability Option permitting the oven to be changed to Reliability mode in order to check the reliability
of the different components of the oven. To do so, one of the four pre-established programmes should be selected.
To start the selected programme, press the button on the wheel. The existing reliability programmes are listed
below. These should all be run repeatedly until the user decides to exit the current operating mode. The reliability
programme being run should be displayed at all times (programme + time elapsed), together with the data given in
each of the programmes, alternating the 2 messages (5 seconds for the first, 5 seconds for the second).
Reliability programme 1
o This is the sequence which should be repeated:
o 8 minutes Convection Mode at 300 ºC
o 8 minutes Mixed Mode at 250 ºC
o 8 minutes Steam Mode
Reliability programme 2
o The oven will operate in Convection Mode at 99 ºC. The fluepipe is activated every 30 seconds, going up or
down depending upon the initial position.
Reliability programme 3
o The oven will operate in Convection Mode at 300 ºC. The VE output should be kept lit if 70<NTC>75ºC.
Reliability programme 4
o The oven operates in Mixed Mode at 250ºC. Every 30 seconds the direction of the fan with R/L is changed.
Reliability programme 5
o Not enabled.
M40 Log option for viewing the oven log. To start, press the button on the wheel.
To go from one section to the next, use the wheel.
Press the button on the wheel for 5 seconds to reset the value displayed.
M1 H Prg Conve -
Total hours of operation in Convection mode.
M2 H Prg Mixed -
Total hours of operation in Mixed mode.

Table of Contents